Visit us at Medicall Exhibition at Hall# 5, Stall# E13, from 7th ~ 9th October 2023, at Pragati Maidan, New Delhi, India
Visit us at Medicall Exhibition at Hall# 5, Stall# E13, from 7th ~ 9th October 2023, at Pragati Maidan, New Delhi, India

Products > Respiratory Care > Respiratory Humidifier > CH580

CH580

Respiratory Humidifier

CH580

Respiratory Humidifier

The CH580® Respiratory Humidifier is designed to warm and add humidity to gases, which are delivered to the patient requiring artificial respiration using a respiratory care equipment, such as ventilators, BiPAPs, CPAPs, etc., where the gas flow remains at constant level.
The CH580® can be used on patients of all age groups, requiring any kind of invasive OR non-invasive artificial respiration.
The gas flows through heated water surface and then warmed and humidified, based on the mode setting selected (invasive mode / non-invasive mode) on the front control panel. The temperature of the gas delivered to the patient (patient end temperature) is monitored using the temperature probe and displayed on the unit. The patient end temperature and chamber temperature are controlled by humidifier based on the mode setting selected.

The CH580® Respiratory Humidifier is designed to warm and add humidity to gases, which are delivered to the patient requiring artificial respiration using a respiratory care equipment, such as ventilators, BiPAPs, CPAPs, etc., where the gas flow remains at constant level.
The CH580® can be used on patients of all age groups, requiring any kind of invasive OR non-invasive artificial respiration.
The gas flows through heated water surface and then warmed and humidified, based on the mode setting selected (invasive mode / non-invasive mode) on the front control panel. The temperature of the gas delivered to the patient (patient end temperature) is monitored using the temperature probe and displayed on the unit. The patient end temperature and chamber temperature are controlled by humidifier based on the mode setting selected.

Salient Features

Specifications

Device Characteristics

Thermal Cutout110 + 6 °C
Warm-up Period< 30 minutes
Input Flow RangeUpto 40 lpm with humidity output > 33mg/L (Invasive Mode)
Upto 80 lpm with humidity output > 10mg/L (Non-Invasive Mode)
DisplayThree Digit, 14 mm, 7 Segment Green LED Display
Temperature Display Range10 ~ 70 °C
Temperature Display Resolution+ 0.1 °C
Temperature Display Accuracy+ 0.5 °C (in the temperature range of 25~45 °C)
Default Temperature DisplayLower of the Airway / Chamber Temperature
AlarmsHigh Temperature Alarm, Low Temperature Alarm, Probe Disconnect / Sensor Failure Alarm

Electrical Characteristics

Power Supply 230 VAC ± 10%, 50/60 Hz, Sine Wave
Heater Plate Capacity 150 W (at nominal mains voltage)
Heater Wire Rating 22 + 5 VAC; 30 W; 1.36 Amp (Max)
Electrical Fuse 2 x 2 Amp, 250V, Fast blow (for Main Unit);
1 x 4 Amp, 250V, Fast Blow (for Heater-Wire)

Physical Characteristics

Dimensions (L x W x H) 165 x 135 x 155 mm³
Weight 3.0 kg

Environmental Characteristics

Temperature Range Operation: 18 ~ 26 °C Storage: -10 ~ 50 °C
Relative Humidity Range Operation: Upto 85% (non-condensing) Storage: Upto 95%
Ambient Pressure Range Upto 20 kPa

Classification & Compliances

Device Classification Continuous Operations, Class I, Type B, Drip Proof IPX1; Non-Sterile, Active Medical Device – AC
Compliances & Certifications IEC 60601-1 (Safety); IEC 60601-1-2 (EMC)
Intended Patient Population Neonate, Pediatric and Adult (All age group of patients; requiring non-invasive ventilation)

Accessories

  • Temperature Probe (Standard)
  • Heater-Wire Adaptor for Single Limb Disposable Circuit (Optional) 
  • Heater-Wire Adaptor for Dual Limb Disposable Circuit  (Optional) 
  • Heater-Wire Adaptor for Single Limb Reusable Circuit (Optional) 
  • Heater-Wire Adaptor for Single Limb Reusable Circuit (Optional) 
  • Flat Mounting Clamp  (Optional)

Note: Product specifications, part / model numbers, and accesories options are subject to change, without prior notice.

Related Products