Products > Respiratory Care > Respiratory Humidifier > CH510
CH510
Respiratory Humidifier
CH510
Respiratory Humidifier
The CH510® Respiratory Humidifier is designed to warm and add humidity to gases, which are delivered to the patient requiring artificial respiration using a respiratory care equipment, such as ventilators, BiPAPs, CPAPs, etc., where the gas flow remains at constant level.
The CH510® can used on patients of all age groups, requiring non-invasive artificial respiration, such as continuous positive airway pressure (CPAP) therapy OR masked ventilation, via face, nasal OR oral mask.
The gas flows through heated water surface and then warmed and humidified, based on the setting on the front control panel. The temperature of the gas delivered to the patient (patient end temperature) is monitored using the temperature probe and displayed on the unit. The patient end temperature is controlled by humidifier based on the temperature control setting selected.
The Respiratory Humidifier is designed to warm and add humidity to gases, which are delivered to the patient requiring artificial respiration using a respiratory care equipment, such as ventilators, BiPAPs, CPAPs, etc., where the gas flow remains at constant level.
The CH510® respiratory humidifier is used on patients of all age groups, requiring non-invasive artificial respiration, such as continuous positive airway pressure (CPAP) therapy OR masked ventilation, via face, nasal OR oral mask.
The gas flows through heated water surface and then warmed and humidified, based on the setting on the front control panel. The temperature of the gas delivered to the patient (patient end temperature) is monitored using the temperature probe and displayed on the unit. The patient end temperature is controlled by humidifier based on the temperature control setting selected.
Salient Features
- Compact, Light Weight & Easy to Operate
- Servo Controlled with Built-in Overheat Protection
- With Heater-Wire Functionality
- Easy to Read Patient’s Airway Temperature and Alarms
- User Adjustable, Three Level Digital Temperature Control
- Adaptable with all Respirators
Specifications
Device Characteristics
Thermal Cutout | 95 + 5 °C |
Warm-up Period | < 30 minutes |
Input Flow Range | 5 ~ 60 lpm |
Display | Three Digit, 14 mm, 7 Segment Green LED Display |
Temperature Display Range | 10 ~ 70 °C |
Temperature Display Resolution | + 0.1 °C |
Temperature Display Accuracy | + 0.5 °C |
Alarms | High Temperature Alarm, Low Temperature Alarm, Probe Disconnect / Sensor Failure Alarm |
Electrical Characteristics
Power Supply | 230 VAC ± 10%, 50/60 Hz, Sine Wave |
Heater Plate Capacity | 150 W (at nominal mains voltage) |
Heater Wire Rating | 22 + 5 VAC; 30 W; 1.36 Amp (Max) |
Electrical Fuse | 2 x 2 Amp, 250V, Fast blow (for Main Unit); 1 x 4 Amp, 250V, Fast Blow (for Heater-Wire) |
Physical Characteristics
Dimensions (L x W x H) | 165 x 135 x 155 mm³ |
Weight | 3.0 kg |
Environmental Characteristics
Temperature Range | Operation: 18 ~ 26 °C Storage: -10 ~ 50 °C |
Relative Humidity Range | Operation: Upto 85% (non-condensing) Storage: Upto 95% |
Ambient Pressure Range | Upto 20 kPa |
Classification & Compliances
Device Classification | Continuous Operations, Class I, Type B, Drip Proof IPX1; Non-Sterile, Active Medical Device – AC |
Compliances & Certifications | IEC 60601-1 (Safety); IEC 60601-1-2 (EMC) |
Intended Patient Population | Neonate, Pediatric and Adult (All age group of patients, requiring non-invasive ventilation) |
Accessories
- Temperature Probe (Standard)
- Heater-Wire Adaptor for Single Limb Disposable Circuit (Optional)
- Heater-Wire Adaptor for Dual Limb Disposable Circuit (Optional)
- Heater-Wire Adaptor for Single Limb Reusable Circuit (Optional)
- Heater-Wire Adaptor for Single Limb Reusable Circuit (Optional)
- Flat Mounting Clamp (Optional)
Note: Product specifications, part / model numbers, and accesories options are subject to change, without prior notice.