Products > Respiratory Care > Respiratory Humidifier > CH510

CH510

Respiratory Humidifier

CH510

Respiratory Humidifier

The CH510® Respiratory Humidifier is designed to warm and add humidity to gases, which are delivered to the patient requiring artificial respiration using a respiratory care equipment, such as ventilators, BiPAPs, CPAPs, etc., where the gas flow remains at constant level.
The CH510® can used on patients of all age groups, requiring non-invasive artificial respiration, such as continuous positive airway pressure (CPAP) therapy OR masked ventilation, via face, nasal OR oral mask.
The gas flows through heated water surface and then warmed and humidified, based on the setting on the front control panel. The temperature of the gas delivered to the patient (patient end temperature) is monitored using the temperature probe and displayed on the unit. The patient end temperature is controlled by humidifier based on the temperature control setting selected.

The Respiratory Humidifier is designed to warm and add humidity to gases, which are delivered to the patient requiring artificial respiration using a respiratory care equipment, such as ventilators, BiPAPs, CPAPs, etc., where the gas flow remains at constant level.
The CH510® respiratory humidifier is used on patients of all age groups, requiring non-invasive artificial respiration, such as continuous positive airway pressure (CPAP) therapy OR masked ventilation, via face, nasal OR oral mask.

The gas flows through heated water surface and then warmed and humidified, based on the setting on the front control panel. The temperature of the gas delivered to the patient (patient end temperature) is monitored using the temperature probe and displayed on the unit. The patient end temperature is controlled by humidifier based on the temperature control setting selected.

Salient Features

Specifications

Device Characteristics

Thermal Cutout 95 + 5 °C
Warm-up Period < 30 minutes
Input Flow Range 5 ~ 60 lpm
Display Three Digit, 14 mm, 7 Segment Green LED Display
Temperature Display Range 10 ~ 70 °C
Temperature Display Resolution + 0.1 °C
Temperature Display Accuracy + 0.5 °C
Alarms High Temperature Alarm, Low Temperature Alarm, Probe Disconnect / Sensor Failure Alarm

Electrical Characteristics

Power Supply 230 VAC ± 10%, 50/60 Hz, Sine Wave
Heater Plate Capacity 150 W (at nominal mains voltage)
Heater Wire Rating 22 + 5 VAC; 30 W; 1.36 Amp (Max)
Electrical Fuse 2 x 2 Amp, 250V, Fast blow (for Main Unit);
1 x 4 Amp, 250V, Fast Blow (for Heater-Wire)

Physical Characteristics

Dimensions (L x W x H) 165 x 135 x 155 mm³
Weight 3.0 kg

Environmental Characteristics

Temperature Range Operation: 18 ~ 26 °C Storage: -10 ~ 50 °C
Relative Humidity Range Operation: Upto 85% (non-condensing) Storage: Upto 95%
Ambient Pressure Range Upto 20 kPa

Classification & Compliances

Device ClassificationContinuous Operations,
Class I, Type B, Drip Proof IPX1;
Non-Sterile, Active Medical Device – AC
Compliances & CertificationsIEC 60601-1 (Safety);
IEC 60601-1-2 (EMC)
Intended Patient PopulationNeonate, Pediatric and Adult (All age group of patients,  requiring non-invasive ventilation)

Accessories

  • Temperature Probe (Standard)
  • Heater-Wire Adaptor for Single Limb Disposable Circuit (Optional) 
  • Heater-Wire Adaptor for Dual Limb Disposable Circuit  (Optional) 
  • Heater-Wire Adaptor for Single Limb Reusable Circuit (Optional) 
  • Heater-Wire Adaptor for Single Limb Reusable Circuit (Optional) 
  • Flat Mounting Clamp  (Optional)